A Title 24 report does not always pass on the first calculation, and even a passing CF1R may need to be revised later if the construction drawings or equipment selections change. In most residential projects, the problem is not that the entire design is inefficient. More often, a few details—such as window performance, insulation, HVAC specifications, or inconsistencies between the plans and the energy model—need to be corrected.

title 24 report

What Does It Mean When a Title 24 Report “Fails”?

For projects using the performance method, approved compliance software compares the proposed building against the Energy Code baseline. If the proposed design does not meet the required energy budget, changes are needed before the Certificate of Compliance can be finalized. The 2025 Energy Code allows performance modeling specifically so different building components can be evaluated together rather than requiring every component to follow a single prescriptive solution.

A report can also pass the energy calculation but still require revision if the information in the CF1R does not match the permit drawings.

Compliance Issues Table
SITUATION WHAT HAPPENS TYPICAL CAUSE USUAL SOLUTION
ENERGY MODEL DOES NOT COMPLY Calculation shows insufficient compliance margin Envelope or equipment performance Improve selected measures
CF1R AND PLANS DISAGREE Plan reviewer requests correction Design changed after modeling Update report or drawings
REQUIRED INFORMATION IS MISSING Report cannot be finalized accurately Incomplete plans Obtaining missing information
WRONG COMPLIANCE PATH IS USED Forms may need to be replaced Incorrect project classification Reevaluate scope and form type

Window Information Is a Common Problem

Windows can significantly influence residential energy performance. Their size, orientation, U-factor, and Solar Heat Gain Coefficient (SHGC) are all considered by the Energy Code.

Problems often occur when the architectural window schedule changes after the energy model has already been prepared.

Window Issues Table
WINDOW ISSUE WHY IT MATTERS EXAMPLE POSSIBLE CORRECTION
HIGHER U-FACTOR More heat transfers through the window 0.30 specified instead of 0.24 Select better-performing glazing
HIGHER SHGC More solar heat enters the home Large west-facing windows Lower SHGC
WINDOW AREA INCREASES More glazing changes envelope performance Larger sliding door added Update the energy model
ORIENTATION CHANGES Solar exposure changes Window moves from north to west Recalculate the project
architectural window

Insulation and Building-Envelope Details

Missing or inconsistent insulation information is another frequent reason a report needs correction. Wall construction, ceiling or roof insulation, raised floors, and other envelope assemblies should match between the architectural drawings and the CF1R.

Common Envelope Issues Table
COMMON ISSUE WHAT THE REPORT NEEDS TYPICAL PLAN PROBLEM POSSIBLE FIX
WALL INSULATION UNCLEAR Insulation value and assembly Plans only say “insulated wall” Add specific R-value
ROOF ASSEMBLY CHANGES Accurate roof/ceiling construction Attic changed to vaulted ceiling Update energy model
FLOOR TYPE INCORRECT Correct thermal boundary Raised floor modeled as slab Correct construction type
INSULATION REDUCED Actual installed value R-value changed during design Recalculate or restore specification

The California Energy Commission’s residential compliance manual provides separate requirements for building-envelope components including fenestration, insulation, roofs, and floors.

wall construction

HVAC and Duct Changes

HVAC changes can affect both the energy calculation and the field-verification requirements shown on the CF1R.

For example, replacing equipment, modifying ducts, changing system efficiency, or switching between ducted and ductless systems may change the required compliance documentation. Under the 2025 Energy Code, certain alterations also trigger duct-leakage testing and ECC verification requirements.

HVAC Changes Table
HVAC CHANGE POSSIBLE EFFECT EXAMPLE RECOMMENDED ACTION
EQUIPMENT EFFICIENCY CHANGES Energy performance changes Different heat-pump model selected Update equipment data
DUCT LOCATION CHANGES Distribution losses may change Ducts moved into attic Recheck calculations
EXISTING DUCTS ARE ALTERED Testing may be triggered HVAC system replacement Confirm ECC requirements
SYSTEM TYPE CHANGES Compliance strategy may change Ducted system becomes mini-split Revise mechanical inputs

The Plans and CF1R Must Stay Consistent

One of the easiest problems to avoid is a mismatch between the energy report and the final drawings.

If an architect changes a window, insulation value, HVAC system, water heater, or conditioned floor area after the Title 24 report is prepared, the energy consultant should review the change before permit submission.

The CF1R is intended to demonstrate that the project design and equipment are compliant at the time of permit application.

How Can Revisions Be Minimized?

The best approach is simple: provide a coordinated plan set and avoid finalizing the CF1R while important design decisions are still changing.

A draft review is also valuable. Checking the project address, floor area, windows, insulation, HVAC system, and water heater before registration can catch many problems early.

Need Help With a Title 24 Revision?

If your project has received plan-check comments or the design has changed after the original CF1R was prepared, send us the latest drawings and the existing report. We can review the changes and determine what needs to be updated.